● Overall thermal protection performance TPP(cal/cm) : ≥34.
● Weight of the whole set: ≤3.1kg.
● Flame retardant performance: outer damage length (warp, weft ≤30mm); Damage length of heat insulation layer (longitude and latitude ≤34mm); Damage length of comfort layer (longitude and latitude ≤37mm).
● Breaking strength: outer layer (longitude ≥1200N, latitude ≥1170N); Comfort layer (longitude ≥385N, latitude ≥360N).
● Outer tearing strength: warp ≥310N, weft ≥300N.
● Thermal stability performance: After the thermal stability performance test, the size change rate of the outer layer is ≤1%, the size change rate of the waterproof breathable layer is ≤2%, the size change rate of the insulation layer is ≤1%, the size change rate of the outer strengthening material is ≤1%, and the size change rate of the comfort layer is ≤3%, and the sample surface should not change significantly.
● Reflective mark with flame retardant performance: warp, weft damage length ≤25mm; Flame retardant properties of the outer reinforced material: warp damage length ≤31mm, weft damage length ≤26mm.
● Waterproof breathable layer: hydrostatic pressure: ≥50KPa; Oil rejection performance ≥3; Moisture permeability ≥6350g/m2·24h.
● Shrinkage rate: the dimension change rate of the outer layer is ≤1%, the dimension change rate of the waterproof breathable layer is ≤1.5%, the dimension change rate of the heat insulation layer is ≤1.2%, and the dimension change rate of the comfort layer is ≤1.5%.
● Joint breaking strength: outer layer longitude ≥920N, latitude ≥760N.
● Provide the inspection report of the national fire equipment Quality supervision and inspection Center.
● Technical performance XF10-2014 "Firefighter fire protective clothing" standard requirements, the use of four layers of structure, respectively, outer layer, waterproof breathable layer, heat insulation layer and comfort layer.