● Flame retardant performance: outer damage length (longitude, latitude ≤22mm); Damage length of waterproof breathable layer (heat insulation layer) (longitude and latitude ≤41mm); Damage length of comfort layer (warp and latitude ≤33mm).
● Breaking strength: outer layer (longitude ≥2300N, latitude ≥2280N); Comfort layer (longitude ≥450N, latitude ≥380N).
● Outer tearing strength: longitude ≥1090N, latitude ≥910N.
● Thermal stability performance: After the thermal stability performance test, the size change rate of the outer layer is ≤1%, the size change rate of the waterproof breathable layer is ≤2%, the size change rate of the outer strengthening material is ≤1%, and the size change rate of the comfort layer is ≤3%, and the sample surface should not change significantly.
● Reflective mark with flame retardant performance: warp, weft damage length ≤22mm; Flame retardant properties of the outer reinforced material: warp and weft damage length ≤21mm.
● Waterproof breathable layer: hydrostatic pressure: ≥50KPa; Oil rejection performance ≥3; Moisture permeability ≥5950g/m2·24h.
● Shrinkage rate: the dimension change rate of the outer layer is ≤0.7%, the dimension change rate of the waterproof breathable layer is ≤1.2%, and the dimension change rate of the comfort layer is ≤1.3%.
● Joint breaking strength: outer layer longitude ≥1090N, latitude ≥985N.
●Provide the inspection report of the national fire equipment Quality supervision and inspection Center.
● The technical performance meets the requirements of XF 10-2014 "Firefighter fire protective clothing" standard. The three-layer structure is used, which is an outer layer, a waterproof breathable layer and a comfortable layer.