Home About Product News Case Down Honor Contact CN
Firefighter's fire command uniform
● The upper and lower split structure, the overlapping part between the shirt and the pants should not be less than 340mm.
● Collar: The collar is a standing collar, the front collar is equipped with a collar, and the inside of the collar is made of smooth skin and comfortable fabric.
● Reflective identification belt: the top is provided with a 360-degree circular reflective identification belt on the chest, hem and cuff, and the pants are provided with a 360-degree circular reflective identification belt on the small leg. The reflective tape is 50.8mm(2 inches) wide and silver yellow in color. The center of the back of the garment is sprayed with fire-resistant, waterproof and fluorescent materials, and the font, color, font size and spacing meet the requirements of the pattern;
● Pants crotch: The crotch of pants adopts the integrated design; Trouser braces. With H-type strap, strap should be adjustable length, removable.
Consult Now
Main structure
● The upper and lower split structure, the overlapping part between the shirt and the pants should not be less than 340mm.
● Collar: The collar is a standing collar, the front collar is equipped with a collar, and the inside of the collar is made of smooth skin and comfortable fabric.
● Reflective identification belt: the top is provided with a 360-degree circular reflective identification belt on the chest, hem and cuff, and the pants are provided with a 360-degree circular reflective identification belt on the small leg. The reflective tape is 50.8mm(2 inches) wide and silver yellow in color. The center of the back of the garment is sprayed with fire-resistant, waterproof and fluorescent materials, and the font, color, font size and spacing meet the requirements of the pattern;
● Pants crotch: The crotch of pants adopts the integrated design; Trouser braces. With H-type strap, strap should be adjustable length, removable.
● Top front flap zipper size is not less than 8.
Accessory structure
● Pocket: the left chest of the jacket is equipped with a stereo radio pocket, the inside is equipped with an inside insert bag, and the bottom is equipped with an outside paste bag. 1 tool bag for each outer thigh. All outer pockets are equipped with leak holes.
● Left arm Velcro: A 90mm×110mm shield Velcro is set on the outside of the left upper arm with a shield logo.
● Cuff: The cuff is designed in circular arc, the outer material is wrapped, the tightening adjusting loop is set, and the rib protective wrist guard is configured, the rib protective wrist guard has a thumb hole, and the internal waterproof cloth is set.
● Top flap: Top flap Velcro is through; The bottom of the jacket. Top comfort layer hem set waterproof cloth.
● The bottom of the trousers. The bottom of the trousers adopts circular design, the inside is provided with waterproof cloth, the inside is provided with zipper, and the bottom is covered with leather material.
● Reinforcing treatment: Shoulder, elbow and knee should be thickened with wear-resistant layer, which should be soft and easy to clean.
● The left and right shoulders are provided with two hanging loops.
Technical performance
● Overall thermal protection performance TPP(cal/cm) : ≥34.
● Weight: ≤3.2kg.
● Flame retardant performance: outer damage length (warp, weft ≤30mm); Damage length of heat insulation layer (longitude and latitude ≤35mm); Damage length of comfort layer (longitude and latitude ≤37mm).
● Breaking strength: outer layer (longitude ≥1200N, latitude ≥1180N); Comfort layer (longitude ≥390N, latitude ≥365N).
● Outer tearing strength: warp ≥310N, weft ≥305N.
● Thermal stability performance: After the thermal stability performance test, the size change rate of the outer layer is ≤1%, the size change rate of the waterproof breathable layer is ≤2%, the size change rate of the insulation layer is ≤1%, the size change rate of the outer strengthening material is ≤1%, and the size change rate of the comfort layer is ≤3%, and the sample surface should not change significantly.
● Reflective mark with flame retardant performance: warp, weft damage length ≤25mm; The flame retardant performance of the outer reinforced material: the warp and weft damage length is less than 30mm, and there is no melting and dripping phenomenon.
● Waterproof breathable layer: hydrostatic pressure: ≥50KPa; Oil rejection performance ≥3; Moisture permeability ≥6300g/m2·24h.
● Shrinkage rate: the dimension change rate of the outer layer is ≤1%, the dimension change rate of the waterproof breathable layer is ≤1.5%, the dimension change rate of the heat insulation layer is ≤1.2%, and the dimension change rate of the comfort layer is ≤1.5%.
● Joint breaking strength (N) : outer layer longitude ≥935N, latitude ≥780N.
● Provide a copy of the inspection report of the National fire equipment Quality Supervision and Inspection Center.
● The technology meets the requirements of XF 10-2014 "Firefighter fire Protection clothing" and adopts four layers of structure, namely outer layer, waterproof and breathable layer, heat insulation layer and comfort layer.