Home About Product News Case Down Honor Contact CN

Performance of firefighter RHJ500B

2024/10/22 13:49:56
● The technical performance meets the standard requirements of GB27900-2011 "Fireman's alarm".
● The appearance of the structure should be complete, the surface without obvious spots, bubbles, cracks and scars, the shell wrapped in bulletproof glue.
● Explosion-proof grade: no less than Ex ib IIC T4 Gb, copy of explosion-proof certificate provided.
● Waterproof performance: The rescuer is placed in a container with a water depth of 1.5 meters for 2 hours, and should not be entered.
● Climatic environmental performance and mechanical environmental performance should meet the standard requirements.
● The predictive alarm function, automatic alarm function, manual alarm function and low voltage alarm function should meet the standard requirements.
● Insulation performance: ≥550MQ under normal conditions, ≥550MQ after wet heat test.
● Allowable rest time: 30±1s.
● Warning time: 15±1s.
● Forecast alarm level intensity: ≥103dB.
● Alarm sound level intensity: ≥101dB.
● Continuous alarm time: ≥600min.
● Continuous startup time: ≥123h.
● Luminous brightness: > 300cd/m².
● Mass ≤220g.
● Provide a copy of the inspection report of the National fire equipment Quality Supervision and Inspection Center.